#15367 closed enhancement (fixed)
Power transformer extension
Reported by: | francois.lacombe | Owned by: | team |
---|---|---|---|
Priority: | normal | Milestone: | 18.05 |
Component: | Internal preset | Version: | |
Keywords: | power, transformer | Cc: |
Description (last modified by )
Hi,
An extension proposal had been accepted regarding power transformer mapping. Both power transformer and power pole with transformer presets should be updated.
https://wiki.openstreetmap.org/wiki/Proposed_features/Transformer_extension_proposal
Tagging of power=transformer has been updated accordingly
https://wiki.openstreetmap.org/wiki/Tag:power%3Dtransformer#Tagging
User should be prompted for the following tags (with according label), out of casual ones :
- transformer= {distribution, generator, converter, traction, auto, phase_angle_regulator, auxiliary, yes} (Function of transformer)
- location=* (Transformer location)
- phases=* (Number of phases)
- frequency=* (Operating frequency)
- voltage:primary=* (Primary "power plant side" voltage)
- voltage:secondary=* (Secondary "consumer side" voltage)
- voltage:tertiary=* (Tertiary "auxiliary side" voltage)
- windings=* (Number of windings)
- windings:configuration = {star, delta, open-delta, zigzag, open, scott, leblanc} (Windings configuration)
- rating=* (Rating in VA)
- devices=* (Number of different transformer devices)
voltage=* key shouldn't be used any more on power transformers.
Additionally, some validation rules should be created as follow and warn users :
- Check rating=* is given in VA and without any unit in the value (like multiples kVA, MVA,...)
- Check voltage=* isn't associated with power=transformer or transformer keys
Thank you in advance to take care of this, all the best.
Attachments (0)
Change History (7)
comment:1 by , 7 years ago
Description: | modified (diff) |
---|
comment:2 by , 7 years ago
Component: | External preset → Internal preset |
---|
comment:3 by , 7 years ago
comment:4 by , 7 years ago
I might add that, for poles with transformer, a switch=*
preset could be very useful, as these poles often have switches to cut the line departing from the transformer.
comment:5 by , 7 years ago
Hi Penegal,
Please read this about the power preset on iD where I try to convince them about rating without unit tagging.
https://github.com/openstreetmap/iD/issues/4442
I definitely believe it's great, but that's not everyone opinion.
I write you a more detailed mail about low volvate circuit breakers beside transformers.
Francois
comment:6 by , 7 years ago
Milestone: | → 18.05 |
---|
I agree with that request, especially the new
voltage:*
tagging, which significantly improves power tagging.@francois.lacombe: I think the only check to do about
rating
is that it must be a number, as JOSM won't be able to check by itself if it's in VA.